Light-Pipe LED Displays

Pertronic

LP Display Board

Pertronic Light Pipe Display Units (PDB12 and PDB8) are repeater / mimic displays that connect to the RS-485 Mimic Bus of the following Pertronic products:

  • F220 fire panel
  • F100A & F120A fire panels
  • F16e fire panel
  • F4-RMAX
  • F220 & Net2 Network Card (NET2CARD)
  • F100/F120 Network Card (NETCARD)

The PDB12 provides:

  • Four LED global indicators (Sprinkler, Fire, Defect and Normal)
  • Eight 8 LED zone indicators
  • Ancillary TPIC Bus for driving 8-Way LED display units (PDB8) and 8-Way Relay Boards (F100ZDRLY)

Eight-way display boards (PDB8) and eight-way relay boards (F100ZDRLY) may be daisy-chained to the ancillary TPIC bus, expanding the number of LEDs up to the maximum capacity of the fire panel or network card. LED and relay outputs are mapped in the fire panel configuration as LED outputs.

The Ancillary TPIC Bus is supervised for faults, and supplies DC power to daisy-chained LED and relay boards.

Pertronic light pipe LED display units are designed for two configurations. The boards may be installed in Pertronic fire panels or Pertronic mimic cabinets with the light pipes protruding through holes in a display board, to create a local or remote index display. In this configuration, unused LEDs may be covered with individual blanking plugs. Pertronic Industries provide a range of cabinets for remote index displays.

Alternatively, Pertronic Light Pipe LED Display Units may be used in custom-built LED displays. Each display unit provides a set of open drain (pull-down”) outputs for driving remote mounted LEDs, via a header connector on the PCB.

A cable assembly is available for remote mounted LEDs. The assembly includes 500 mm of cable, LEDs, and mounting bezels, and is available with green, yellow, or green LEDs.

Features

  • PDB12 can drive multiple PDB8 or F100ZDRLY output/display units
  • Fault supervision
  • Optional steady or flashing display
  • Configured in panel configuration as LED Mimic
  • Address on RS485 bus set by jumpers
  • Pulldowns for external LEDs:
    • PDB12: 12 x LED pull downs
    • PDB8: 8 x LED pull downs
  • Onboard system function inputs (PDB12 only):
    • Evacuation, BCO, Acknowledge, Door Interlock, Door Switch, External Defect
  • Four onboard system function outputs (PDB12 only)
    • Evacuation, Silence Alarms, Bells, Buzzer
  • Onboard fault diagnostic LED indicator
  • Supplied complete with mounting stand-offs
  • The 8-way display board (PDB8) is supplied complete with one TPIC bus ribbon lead