This is a draft site

AA Conventional Zone Interface Module

Parent products

The Conventional Zone Interface (M210EA-CZR) links a conventional detection zone to a Pertronic intelligent addressable fire panel (such as the F220), via the addressable loop.

The conventional detection zone can be powered from the intelligent addressable loop circuit, or from an external 24 V dc power supply. Where the conventional zone is powered from an external power supply, the loop is fully isolated from the conventional zone and from the power supply.

The M210EA-CZR may be used with detection zones in hazardous areas requiring intrinsically safe equipment. For hazardous area applications, a suitable intrinsically safe barrier must be used. Please refer to the Installation Instructions for details.

The M210EA-CZR has a single tri-colour green/red/yellow LED, which can be set by panel command to pulse green each time the module is polled. The fire panel can be configured to switch the red indicator on continuously in the event of an alarm. The indicator blinks yellow if the module detects a power supply fault, detection zone fault, or a short-circuit on the loop.

Features:

  • Individually addressable by the fire panel
  • Detection zone supervised for open-circuit and short-circuit faults
  • Inbuilt current limiting resistor
  • Powered by loop circuit or 24 volt dc external power supply
  • Tri-colour indicator LED
  • Automatic detection of short-circuits on intelligent addressable circuit
  • Short-circuit isolator
  • Optional isolator bypass
  • Screwdriver operated rotary address switches, accessible from front and one side
  • Clips for top hat 35 mm DIN rail
  • Indicator LEDs and address switches accessible and visible in both DIN-rail and surface mount installations
  • Two mounting holes
  • Fits M200E-SMB surface-mount box
  • Compatible with Pertronic F220 and F100A fire panels
  • Uses one address on the intelligent addressable circuit
  • Supplied complete with one 3.9 kΩ end of line resistor
  • ActivFire listed (afp-3765) to AS ISO 7240.17:2015 and AS ISO 7240:18:2015
  • Direct replacement for M210E-CZR in existing Pertronic systems

NOTE: When the M210EA-CZR is used with an intrinsically safe barrier, a short circuit on the hazardous area side of the barrier will trigger an alarm. Only a short on the module side of the safety barrier will generate a fault signal.

 

Ordering Information

Product Code

Description

Product Code: M210EA-CZR
Description: AA Euro Conventional Zone Module (A) (Uses M200E-SMB Box)

SIGN UP FOR OUR NEWSLETTER