Detectors
Thermistor Heat Detector
Conventional thermistor indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-approved
Thermistor Heat Det. Weatherproof
Conventional thermistor indicating heat detectors. Weatherproof. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-approved
Thermistor Heat Detector w Remote
Conv. thermistor indicating heat detectors Terminals for remote indicator Alarm threshold: 57 °C (blue), 77 °C (yellow) NZS 4512-approved
2251TMBPI Detector
"Acclimate" multi-criteria detector with photoelectric smoke sensor and 63 °C fixed (static) temperature thermistor heat sensor
5251BPI Detector
Analogue addressable heat detector with 57 °C fixed (static) temperature threshold
5251RB-WP Detector
Weatherproof AA rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold, including special base
5251RBPI Detector
Analogue addressable rate of temperature rise heat detector with 57 °C fixed (static) temperature threshold
5251B-WP Detector
Weatherproof analogue addressable heat detector with 57 °C fixed (static) temperature threshold, including special base
2351TEM Detector
Conventional multi-criteria detector. Photoelectric smoke, configurable as low, medium, or high sensitivity. 58 °C rate of rise heat sensor
5351E Detector
Conventional rate of rise heat detector with 58 °C fixed alarm temperature threshold
IHD*-V
Conventional indicating heat detectors. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant
IHD*EAR-V
Conv. indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant
IHD*EK-V
Conventional encapsulated indicating heat detector & cable for harsh environments. Fixed threshold: 57 °C (blue), 125 °C (black)
IHD*R-V
Conv. indicating heat detectors. Terminals for remote indicator. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512-compliant
HD*-V
Conv. non-indicating heat detectors, with or without encapsulation. Fixed alarm threshold: 57 °C (blue), 77 °C (yellow). NZS 4512:1997-compl
2WTA-B Detector
Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and alarm sounder
4WT-B Detector
Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed alarm threshold
4WTAR-B Detector
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold, sounder, and relay
THD for Freezers
Conventional thermistor indicating heat detector. Fixed alarm threshold: 57 °C NZS 4512 type (blue) Suitable for freezers and cool stores
RTS151KIT Remote Test Station
Remote indicator and test panel with key-switch enabled test mode for duct and beam detectors
DNRW Duct Housing
Analogue addressable watertight non-relay photoelectric duct smoke detector
D4120W Weatherproof Duct Detector
Waterproof 4-Wire Photoelectric Duct Smoke Detector. Fitted with auxiliary relay with two form C (change-over) contacts.
4WTR-B Detector
Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed alarm threshold and relay
PC614 Detector
Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.
LHD
Linear heat detection cable. Please note that Pertronic-Anbesec LHD Cable is preferred for new installations
IHD*E-V
Conventional indicating heat detectors. Encapsulated. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow). NZS 4512-compliant
2012/24AUSI Detector
Photoelectric Smoke Alarm 4-wire, 12 V / 24 V with 9 V battery AS 3786:2014
IHD Kit
Conventional bi-metallic indicating heat detectors with remote sensor. Fixed threshold: 57 °C (blue) or 125 °C (black). NZS 4512-compliant
Thermistor Heat Det. Alk. Resistant
Conv. thermistor indicating heat detectors. Alkaline wash resistant. Fixed alarm threshold: 57 °C (blue) or 77 °C (yellow) NZS 4512-approved
OSI-RIE-34 Beam Detector
Reflected Beam Intelligent Addressable Smoke Detector with swivel-mounted emitter-receiver. Compatible with Pertronic F100A & F220 fire pane
Pertronic-Anbesec LHD Cable
Heat sensing cable with a pair of twisted wires. The internal separator melts at a specific temperature, allowing contact between the wires
2251CPI Detector
C Series Intelligent addressable photoelectric smoke detector with programmable alarm threshold.
5251CPI Detector
C Series Intelligent addressable heat detector with programmable "fixed" temperature threshold.
5251RCPI Detector
C Series analogue addressable "rate of rise" heat detector with programmable temperature threshold.
7251CPI Detector
C Series intelligent addressable plug-in Pinnacle™ high-sensitivity photoelectric smoke detector. Configurable alarm threshold.
Bases
B401 Detector Base
Mounting base for conventional plug-in System Sensor detectors. Available in white and ivory
B501AUS Detector Base
Plug-in base for analogue addressable detectors. Standard depth for 200 series detectors.
WB-1AP Base Enclosure
Base Enclosure for Humid Environments, for use with Base Models: B501AP, B501, B401, B401R
B524RTE Detector Base
Plug-in base with change-over relay for analogue addressable detectors
B501AP Detector Base
Plug-in base for analogue addressable detectors and loop-powered devices. Extra depth to suit alarm devices such as addressable strobes.
Manual Call Points
AAMCP-TWP-MK2 Manual Call Point
Analogue Addressable Weatherproof Manual Call Point - Testable
CPP MCP
Conventional manual call point with rocker switch. Available in red, yellow, and white
CPPFPL Mounting Plate
Fascia panel for flush-mounting Pertronic Manual Call Points in place of large old manual call points (break-glass alarms)
CPTSTPRHTR Call Point Stopper
A tough, transparent, polycarbonate shield and frame that fits over a manual call point, with built-in 230 Vac heater
CPTST series
A tough, transparent, polycarbonate shield and frame that fits over a manual call point. Fitted with warning sounder
MCP DPDT
Double-Pole double-throw non-engraved manual call point. Available in red and white
KACSGW MCP Window
Replacement windows for Manual Call Points, including Snapglaze and Break-Glass types
AAMCP-MOD Module
Analogue Addressable MCP Conversion Module. Interfaces a conventional (NZS 4512) manual call point with a Pertronic AA loop.
CPTST Weatherproof
A tough, transparent, weatherproof polycarbonate shield and frame that fits over a manual call point
PS200 FLAP
Transparent hinged plastic cover for Euro Style manual call points, to reduce false alarms caused by accidental MCP activation
Modules
Isolate Timer Module
The Pertronic Isolate Timer Module isolates a zone for a user-programmed time period, after which the zone is automatically re-enabled
F100LRU Loop Relay
AA output module with 4 individually addressable channels: each with a switched, supervised 24 Vdc output, and a volt-free contact
Solenoid Interface
Interface units which allow allow analogue addressable control modules to activate and supervise a wide range of solenoids
IM-10 Module
Analogue addressable monitoring module with ten individually addressable inputs for normally-open contact devices
CR-6 Module
Analogue addressable control module with six voltage-free form-C (change-over) relay contacts
SC-6 Module
Analogue addressable control module with six supervised relay circuits for switching AC, DC, or audio
AAMCP-MOD Module
Analogue Addressable MCP Conversion Module. Interfaces a conventional (NZS 4512) manual call point with a Pertronic AA loop.
F100ZIPB Opto-Isolated IP Board
Eight-way opto-isolated input board for the Pertronic analogue addressable loop responder and multi-function loop responder
M201EA-240 Module
Intelligent addressable control module with one 2-pole output relay (1 pole NO, 1 pole NC). Built-in loop isolator
M201EA Module
Analogue addressable control module with one output channel. Built-in isolator for the AA loop
M210E-CZR Module
Interface between a conventional detection zone and an AA fire panel. Especially suitable for zones in areas subject to explosive atmosphere
M220EA Module
Analogue addressable monitor module with two input channels. Built-in isolator for the AA loop
M221EA Module
Analogue addressable control & monitor module with two input channels and one output channel. Built-in isolator for the AA loop
F220 Fan Controls
The F220 Fan Control System is used with the F220 fire panel to monitor and control air handling equipment for AS 1670.1-compliant.
F100A Fan Controls
F100A Fan Controls are used in Pertronic F100A, F120A and F220 fire alarm systems. Designed to comply with AS 1670.1-compliant.
Aspirating Smoke Detection
VSP-962 VESDA-E Filter
Genuine replacement two-stage smart filter cartridge for VESDA-E aspirating smoke detectors
AUX24V-1.5PSU-BLK Power Supply
24 Volt 1.5 Amp Auxiliary Power Supply in Lockable Battery Cabinet (FAAST Power Supply)
VHX
High level interface between VESDAnet and a personal computer (PC). Allows a user easily configure, manage and monitor a VESDA network
VSP-005 Filter
It's used to replace filter cartridges in VESDA VLC, VLF, VLP and VLS detectors.
VESDA VSC v3.12
Management application for Xtralis fire and gas detection systems including VESDA and ICAM smoke and gas detectors and ancillary devices
VESDA Aspire Software v3.12
A Windows®-based application for designing and specifying VESDA aspirating smoke detection systems
CLC-MON-N9P Cable
Flexible RS-232 extension lead with DB9 male and DB9 female connectors and straight-through connection
FAAST X Series Filter
30 Micron Filter for FAAST XT, XM & XS Series aspirating smoke detectors.
FAAST LT-200 Filter
Replacement filter for FAAST LT-200 aspirating smoke detectors. Two-Pack
VESDA-E VES-A00-P
Four-inlet aspirating smoke detector with individually-addressable inlet pipes and LED display
VESDA-E VES-A10-P
Four-inlet aspirating smoke detector with individually-addressable inlet pipes and LCD display
FAAST FLEX Aspire v3.10
Windows® app. for designing and specifying FAAST FLEX ASD systems including pipe network configuration. NOTE: Does not support VESDA systems
FAAST FLEX
Single or dual input ASD. Silent operation. Suitable for sub-zero environments down to -40°C. Simple DIP-switch configuration.
VRT-100 Programmer
Programmer for VESDANet devices including VESDA aspirating smoke detectors
VSP-860 Kit
A funnel-shaped sampling nozzle and a kit of parts for installing the nozzle inside a cold storage facility.
FAAST PipeIQ v3.0.0
A Windows®-based application for designing and specifying FAAST aspirating smoke detection systems
Explosive Atmosphere Detection
IST200E Module
Interface module for connecting Y72221 galvanic isolator & 22051EISE detectors to a Pertronic analogue addressable loop circuit
ORB-HT-51151 Detector
Intrinsically safe conventional heat detector with 77°C fixed (static) temperature threshold (BS EN 54-5 Class BS)
MTL5561
Dual interface with galvanic isolation for use with conventional MCPs, fire, heat and smoke detectors located in hazardous areas
ORB-OP-52028 Detector
Intrinsically safe conventional photo-electric smoke detector (BS EN 54-7)
KFD0-CS-EX-1.51P Galvanic Isolator
Single channel galvanic isolator for use with conventional MCPs, fire and smoke detectors located in hazardous areas
M210E-CZR Module
Interface between a conventional detection zone and an AA fire panel. Especially suitable for zones in areas subject to explosive atmosphere
MCP3A
Intrinsically safe conventional manual call point with back-box. Suitable for surface or flush mounting
22051EISE Detector
Intrinsically-safe analogue addressable plug-in photoelectric smoke detector
Y72221
Galvanic isolator for analogue addressable IS detectors. Pepperl & Fuchs type KFD0-CS-Ex1.54-Y2
PS200 FLAP
Transparent hinged plastic cover for Euro Style manual call points, to reduce false alarms caused by accidental MCP activation
WCP3A
Intrinsically safe IP67 weatherproof conventional manual call point with back-box for surface mounting
ISGAIFNZSSAP Interface
Interface for connecting a galvanically-isolated detection zone to a Pertronic conventional FACP (F1, F4, F16e), or Loop Responder